- Risk type
- Health risk / other
- Notifying country
- Germany
- Alert number
- A12/01758/21
The particle/filter retention of the material is insufficient (measured values: as low as 40%). Furthermore, weld points may tear apart generating holes in the mask, and ear straps may break easily. Consequently, the product does not fulfil the health and safety requirements; thus, even if combined with other recommended measures, it may not properly protect.
The product does not comply with the Personal Protective Equipment (PPE) Regulation and with the relevant European standard EN 149.
- Category
- Protective equipment
- Product
- Particle filter mask
Measures
Ban on the marketing of the product and any accompanying measures
Date of entry into force 26/10/2021
Recall of the product from end users
Date of entry into force 26/10/2021
Warning consumers of the risks
Date of entry into force 26/10/2021
-
Year - Week
-